DE EN

Signal- und Bildverarbeitungsfunktionen

Ein kleiner Auszug aus dem Kappa Signal Processing Portfolio

Signal-Processing Features

Digitization 8-bit up to 16-bit signal processing
Edge enhancement Increase contrast at edges
Brightness Increasing of image brightness (offset)
Contrast Contrast increasing/moderation
ACC/DRE Automatic control for contrast and brightness with histogram stretching or equalization
Gamma/LUT Adjustable Gamma function/programmable lookup table
Histogram stretching Contrast/brightness enhancement (using the entire range)
HDRadapt Adaptive luminance algorithm
HDR, High Dynamic Range (16-bit) expanded dynamic range
Filter / Memory Shading correction: adjustable correction (e.g. shading and vignetting)
Recursive filter Adjustable filter for noise reduction by averaging images
Bad pixel correction Correction of defect pixels (hot spots), bright + dark spots
Distortion correction Adjustable correction of pillow-shaped and barrel-shaped distortions
Background image subtraction: Subtraction of a reference image
Circular blanking Circular image window (endoscopy and x-ray applications)
Freeze image Hold current image
Mirror / flip Horizontal/vertical image mirror
Negative image Inversion of the positive image, inverted colors/gray values
Image shift Adjustable X-Y shifting
Zoom Adjustable digital zoom

Color Processing

DCIP CMYG: Color processing for CCD with CyMgYeG Pattern
DCIP RGB Color processing for CCD with Bayer Mosaic Pattern
White balance Automatic or manual white balance
Color saturation Adjustable color saturation
Interpolator Adjustable color saturation

Exposure

AET: Automatic exposure time (adjustable target value)
AGC Automatic gain control (adjustable target value)
Smear Correction Automatic correction of smear effects at short exposure times
Automatic Level Target value for AET + AGC
Exposure normal time: exposure = readout time, short (shutter): exposure < readout time, long: exposure > readout time

Image Format/Readout Modes

ROA, Read out Area: Adjustable image area for partial scan
ROI, Region of Interest adjustable image area with Frame Mask (AOI area of interest)
Binning Adjustable horizontal and vertical binning for noise reduction and higher frame rates, higher sensitivity
Pixel Format (Color Coding) Mono 8, 10, 12, 14, 16, RGB, YUV, RAW
Measurement Window Measurement basis for automatic functions
Readout Mode Multichannel readout 1, 2, 4 free running, reset/restart, trigger, FoD, GFR-Gated Free Running (trigger controlled free running sequence)
Dilution faster images by “thinning out” pixels