DE EN

Measuring Concepts for Cameras

EMVA 1288 up to client-specific measurement concepts

Depending on their applications our clients make quite different demands on our measurement concepts. Where required we work with standards like EMVA 1288 but we also provide all possibilities for clients with own measurement specifications or industry specific requirements which can be more selective or stricter. If required we also develop own measuring machines.

Kappa optronics camera data based on EMVA 1288

EMVA 1288 Measurement Laboratory

Objectified measurements using the EMVA 1288 measuring station enable reliable assessment of development steps and create security when aligning with client requirements. The AEON measurement station consists of an ACC2 light source and Heurisko imaging software.

Standardized Measurement Conditions

The camera is directly connected to a homogenous light source with a defined output, enabling measurements to be carried out under defined and standardized calibrated lighting conditions in absolute units. Based upon the precise measurement of the parameters, different cameras can be compared directly. Using the EMVA measuring station, sensitivity, linearity, noise, dark current, and camera gain are defined according to the standard's specifications.

Specific Client Requirements

Increasingly, client requirements include EMVA 1288-compliant measurements. But for clients who don't work with the EMVA standard, a wide diversity of tests, such as those assessing the suitability of sensors for night vision applications, can be carried out with targeted specificity. Camera features which are not covered by the standard or which are specifically defined by the client are implemented using Kappa's HORST measuring station.

 

Show text in one Show text in slides
Kappa optronics Horst

HORST: Camera measuring station with comprehensive data management

Efficient implementation of client-specific measuremen concepts

The possibilities that usual measuring stations afford for measurement according to EMVA 1288 or ISO standards are too rigid for clients with highly specific requirements. With HORST, the Kappa camera measuring station for image sensors’ and cameras’ characterization, Kappa is taking an innovative approach. HORST offers more comprehensive and flexible possibilities for client-specific needs in executing and documenting tailored measurement concepts.

HORST can do more

HORST offers flexible measurements and analyses of parameters not covered by the EMVA standard. Measurement specifications can be defined specifically, thus meeting the needs of clients whose parameter definitions differ from the standard. With integrated camera control, connection to the device’s data bank and many extras like bar code scanning, HORST is the central instrument for integrating processes at all levels of the company.

Individual for every client and every camera

Within our own company, we automate a variety of processes with HORST, condense our cycles and optimize our documentation. Kappa clients profit from an equally comprehensive as well as specific measurement concept according to defined measurement standards. One service we offer is a product certification complete with comprehensive documentation of the individual values of each camera – in accordance with client standards, ISO standards, or Kappa norms.

Show text in one Show text in slides
Kappa optronics KOSMA

Test and measurement for the toughest requirements

KOSMA, developed in-house

Using an image-based measurement machine developed in-house, we have standardized and simplified our processes, further improved measurement performance, and improved and shortened the time required with automation of alignment processes. The measurement microscope offers exactitude of 1 μm absolutely along all axes for sensor adjustment down to the pixel. A measurement protocol documents the results for every camera.

 

Image-Supported Measurement Machine for Automated Sensor
Calibration

High demands are placed on the micrometer-exact positioning of the sensor in the camera housing. The CCD sensor’s optical axis must be aligned with an exactitude of up to +/- 1 μm per spatial direction on the optical axis of the camera housing. Moreover, the sensor mechanics’ maneuverability must achieve a defined value on each of the 3 axes.

Show text in one Show text in slides
Kappa optronics optic adjustments

Kappa Kollimatoren für MTF Messungen, Sensor- und Optikjustage

Messumgebung auf allerhöchstem Niveau

Mit ultrapräzisen Kollimatoren arbeitet Kappa sowohl bei der Messung der Modulationstransferfunktion (MTF) als auch bei der Justage von Sensor und Optik. Dies ermöglicht eine eindeutige Charakterisierung von optischen Systemen. Wir setzen das Verfahren sowohl in der Entwicklung wie auch in der Produktion ein. Die Konstrukteure sind in der Lage, präzise Ableitungen zur Systemleistung zu treffen. In der Fertigung sichert das Verfahren höchste Präzision bei der Systemzusammenstellung.

Charakterisierung

Die optischen Parameter der Kamerasysteme können mit adaptiertem Objektiv präzise charakterisiert, bewertet und für die Kundenserie reproduziert werden. Dazu gehören beispielsweise:

  • Abbildungsqualität
  • Brennweite
  • Anlagemaß
  • Verzeichnung
  • Bildfeld
  • Schärfentiefe
  • und weitere ...